Friday 4 November 2016

Low price electromagnetic wafer type waste water flow meter manufacture


1. Intelligent electromagnetic flowmeter plugging pipe at any time must be completely filled with media, not in the case of dissatisfaction or empty tube work properly. In the media dissatisfaction with the tube, the flowmeter can be used to raise the rear outlet pipe height of the method so that the media full pipe, to avoid dissatisfaction with the tube and the gas attached to the electrode.
2. There is a vacuum inside the pipe will damage the lining of the flow meter, with special attention.
3. The positive direction of the flow should correspond to the positive direction indicated by the arrow on the flowmeter.
4. Intelligent electromagnetic flowmeter can be installed in a straight pipe can also be installed in the horizontal or inclined pipe, but requires two electrodes in the center of the line in the state.
5. For liquid, solid two-phase fluid, the best vertical installation, the measured medium from top to bottom flow, can wear uniform flow meter lining to extend the service life.
6. The flowmeter ensures that there is sufficient space around the pipe flange for installation and maintenance.
7. If there is vibration in the measuring pipe, there should be a fixed bearing on both sides of the flowmeter.
8. If the measuring medium is heavily polluted liquid, install the flowmeter body in the bypass piping, without draining the process operation, then drain and clean.
9. Installation of PTFE-lined flowmeter, the connection flange bolts should pay attention to uniform tightening, or easy to crush the PTFE lining, preferably with a torque wrench.